Fieldwork
81
d.
The rod man needs to move back by 0.2 feet to
be over the design point. Rather than take
another shot, we will instruct him to use a tape
and place a stake at that location. Tap the
button to store the point.
e.
Enter the following data in the Store Point
(Tape Offset) Dialog Box:
Point Name
:
6
Description
:
Staked
Tape Out/Tape In (+/-)
:
0.2
and tap . This
will result in coordinates for the stored point
that are 0.2 feet further from the total station
than the last shot to the prism.
Note: Negative
Tape Out/Tape In
values are toward the
total station and positive values are away from the
total station.
Point Staking Summary
1.
Open a job that contains the design points that you want to stake.
2.
Check the job settings.
3.
Setup a backsight.
4.
Stake the points from the Stake Points screen.
Komentáře k této Příručce