Survey Pro Reference Manual
R-94
Corner & 2 Lines
The Corner and 2 Lines screen is used to store a point at
the corner of a structure using a reflectorless total
station where a direct measurement to the point is not
possible, but two points on two intersecting lines can be
shot.
Foresight
: is the name of the point that will be stored.
Description
: is the description for the point that will be
stored.
HR: 0.000
: shows that no rod height will be used with
this routine since all shots are direct reflectorless.
: will prompt you to take two shots on Line 1,
which intersects with Line 2 at the point you want to store.
Note: Each shot for a line can be in any location on the
same line. (Shot 1 can be to the left or the right of Shot 2.)
: will prompt you to take two shots on Line 2,
which intersects with Line 1 at the point you want to store.
Note: After all shots are done, the computed elevation is
displayed for the new point. You can either enter a different
elevation or tap OK to accept the computed elevation.
: accesses the Backsight Setup
screen (Page R-78)
where the current backsight can be modified.