Set Command Library
PEM: Setting the Position Elevation Mask
Function This command is used to set the elevation mask used in the
position processing.
Command Format Syntax
$PASHS,PEM,d1[*cc]
Parameters
Example
Setting the elevation mask for position processing to 15
degrees:
$PASHS,PEM,15*05
Relevant Query
Command
$PASHQ,PEM
See also $PASHS,ELM
POP: Setting Internal Update Rate for Measurements and PVT
Function This command allows you to set the updates rate used
internally in the measurements and position processing.
Command Format Syntax
$PASHS,POP,d[*cc]
Parameter Description Range Default
d1 Elevation mask angle, in degrees 0-90° 5
*cc Optional checksum *00-*FF