R-136
Repetition Shots
Survey Repetition Shots.
The Repetition Shots screen is used to perform side shots or traverse
shots using any number of repetitions.
Note: The sequence that the repetition shots are performed is
selected in the Repetition Settings screen (Page R-55).
Foresight: is the name of the point that will be stored.
Number of Sets: is the desired number of sets to shoot
to the backsight and foresight.
Note: One set is equivalent to two shots to the backsight
and foresight point.
HR: is the rod height.
: opens the Smart Target options (Page R-457).
Average (of): shows the average angle or distance to the
foresight from all the shots taken. The value in
parenthesis is the total number of repetitions performed.
Worst Residual: displays the worst residual calculated
from all the sets of the selected measurement type.
Description: is the description for the point that is being stored. This
field appears prior to storing the new point.
Note: A residual is the difference between a single measurement and
the average of all the measurements.
Note: If a residual exceeds the tolerances set in the Repetition
Settings screen (Page R-55), that value is displayed in bold text.